Login
Our Product Database
provides detailed information
on our products.
Username (e-mail):
Password:
Skip Navigation Links
Input and output units




« Previous

Next »

AutroKeeper BN-180
Two AutroKeepers interface two loop controllers (Loop Driver Modules BSD-310) to one AL_Com detection loop by assuring non-conflicting loop access
Read more

Monitoring input unit BN-201
Monitoring input unit connected to the interactive detector loop. For external units.
Read more

Extinguishing control unit BN-221/01
Extinguishing control unit: Loop unit for monitoring and control of extinguishing equipment. IP67. For AutroSafe only.
Read more

Monitored output unit with 7A relay BN-221/02
Monitored output unit, 7A relay, for activation of high current consuming equipment. Typical application: Horns and strobe lights. Maximum load current: 6A@24V, IP67. For AutroSafe only.
Read more

Input unit BN-300
Input unit with one monitored input for connection of external alarm contacts etc. With SelfVerify function. Degree of protection: IP54/IP67
Read more

Input unit BN-300M
Modular input unit with one monitored input, for connection of external alarm contacts etc. Mounting on DIN rail. With SelfVerify function.
Read more

Single Monitored Input Unit BN-303
The monitored I/O unit BN-303 has been designed for use with Autronica’s interactive fire detection systems; Autroprime (1.1.0 or newer versions) and AutroSafe (4.3.1 or newer versions).
Read more

Single Monitored Input/Output Unit BN-304
The Single Monitored Input/Output Unit BN-304 has been designed for use with Autronica’s fire detection systems Autroprime (version 1.1.0 or newer) and AutroSafe (version 4.3.1 or newer), and includes the SelfVerify function.
Read more

Dual Monitored Input/Output Unit BN-305
The Dual Monitored Input/Output Unit BN-305 has been designed for use with Autronica’s interactive fire detection systems, Autroprime and AutroSafe, and includes the SelfVerify function.
Read more

Monitored Fire Alarm Device Control Unit – BN-307
The Monitored Fire Alarm Device Control Unit BN-307 has been designed for use with Autronica’s fire detection systems, AutroSafe and Autroprime.
Read more

Single relay output unit BN-310
Loop relay output unit with 1 potential free output With SelfVerify function. Each unit with its own address. Units with high power consumption requires separate power supply. Degree of protection: IP54/IP67
Read more

Interface unit BN-320
Interface unit for AutroSense 200, AutroFlame and AutroBeam 25. With SelfVerify function. Each unit with its own address. Degree of protection: IP54/IP67
Read more

Door control unit BN-320/2
Interactive door control unit, for control and monitoring of fire doors. Addressable unit. Degree of protection: IP54/IP67
Read more

Monitoring and control unit BN-320/4
AutroSafe monitoring and control unit, for monitoring and/or control of various external equipment, such as control of fire dampers, ventilation valves, fans, lifts, plus fire and smoke hatches. Addressable unit. Degree of protection: IP54/IP67
Read more

Sprinkler control unit BN-320/5
Interactive sprinkler control unit, for monitoring and control from sprinkler systems. Addressable unit. Degree of protection: IP54/IP67
Read more

Door monitoring and control unit BN-320/D-L
Door monitoring and control unit for interfacing external units onto the AutroSafe system. Designed for maritime installations. Connected to detector loop to control and monitor different types of doors.
Read more

Door monitoring and control unit BN-320/D-L2
Door monitoring and control unit for interfacing external units onto the AutroSafe system. Designed for maritime installations. Connected to detector loop to control and monitor different types of doors.
Read more

Door monitoring and control unit BN-320/D-XS, extra small
Standard door monitoring and control unit, extra small interface unit for interfacing external units onto the AutroSafe system. Designed for maritime installations. Connected to detector loop to control and monitor different types of doors.
Read more

Sprinkler valve monitoring unit BN-221/FS
Sprinkler valve monitoring control unit designed for maritime installations. Connected to detector loop. Designed for use with the AutroSafe system and AutroMaster 5000.
Read more

General monitoring and control unit BN-320/GMU-XS, extra small
General monitoring and control unit, extra small, used as an interface for a general monitoring and control to front external equipment on to detector loop. Designed for maritime installations.
Read more

Low location lights unit BN-320/LLL
Low location light unit, used in maritime applications only. The output is used to activate/deactivate the external low location light unit.
Read more

Low location lights unit BN-320/LLL-XS, extra small
Low location light unit, extra small, used in maritime applications only. The output is used to activate/deactivate the external low location light unit.
Read more

Standard control unit BN-320/SV
Standard control unit designed for maritime installations. Connected to detector loop. Designed for use with the AutroSafe system and AutroMaster 5000.
Read more

PowerLoop 4-20 mA input unit BN-342, rack mounted
A general-purpose PowerLoop interface designed for third party detectors connected to the AutroSafe integrated fire and gas system.
Read more

PowerLoop 4-20 mA input unit BN-342, DIN rail mounted
A general-purpose PowerLoop interface designed for third party detectors connected to the AutroSafe integrated fire and gas system.
Read more

PowerLoop 4-20 mA input unit BN-342/EX
A general-purpose PowerLoop interface designed for third party detectors connected to the AutroSafe integrated fire and gas system.
Read more

Input unit BN-500/EX
Input unit with one monitored input, for connection of external alarm contacts etc. With SelfVerify function. Approved for use in hazardous areas. Degree of protection: IP54/IP67
Read more

Input unit BN-500/N
Input unit with one monitored input, for connection of external alarm contacts etc. With SelfVerify function. Approved for use in hazardous areas, zone 2. Degree of protection: IP54/IP67
Read more

Input unit with BNB-300 BN-505/EXD
Input unit with BNB-300 and one monitored input
Read more

Conventional loop interface module BNB-330A
Conventional loop interface module for up to 32 conventional detectors. Conventional loop voltage is selectable to 15 or 24V. Modular unit for mounting on DIN rail.
Read more

Conventional loop interface module BNB-331
2-wire interface unit for interfacing conventional detectors and manual call points onto Autronica’s interactive fire detection systems.
Read more

Local Alarm Delay Unit BN-303LS
The local alarm delay unit BN-303/LS enables delay of alarm routing outside the local area which the unit is connected to (Autroprime; 1 detection zone, AutroSafe; up to 10 detection zones), plus temporary stop of smoke detection in the local area.
Read more

« Previous